An EN590 SGS report is the gatekeeper document that decides whether a diesel cargo clears customs, satisfies a letter of credit and gets paid. The certificate packs 15 mandatory test rows, from Cetane Number down to Lubricity, into a single table where every column carries a specific verification task. Miss a method code mismatch, overlook an asterisk in the conformity column, or apply the wrong seasonal limit and the shipment stalls at the terminal.
This walkthrough uses a redacted EN590 SGS report sample to show exactly how to read each test line. You will learn how to decode the header identifiers that banks check, why the Method column must match the current EN 590 revision, how measurement uncertainty affects the Pass or Fail decision, and which parameters (Cetane Number, Density, Sulphur, FAME, CFPP) most often trigger disputes. By the end you can open any EN590 SGS certificate and confirm every row before the cargo moves.
A redacted EN590 SGS report sample shows every mandatory parameter row from Cetane Number through Lubricity with callout boxes that explain method codes, units, limits and conformity flags. The example table below mirrors the layout SGS uses for a standard B7 grade certificate so buyers can match each cell to the specification in EN 590:2013+A1:2017.
| Parameter | Test Method | Unit | Result | Limit (EN 590) | Conformity |
|---|---|---|---|---|---|
| Cetane Number | ISO 5165 | , | 52.3 | Min 51.0 per DieselNet (current EN 590) | Pass |
| Density at 15°C | ISO 12185 | kg/m³ | 834.2 | 820, 845 | Pass |
| Sulphur Content | ISO 20846 | mg/kg | 7.4 | Max 10.0 per DieselNet (current EN 590 / Fuel Quality Directive) | Pass |
| FAME Content | EN 14078 | % V/V | 6.8 | Max 7.0 (B7) | Pass |
| Oxidation Stability | EN 15751 | hours | 28.5 | Min 20.0 | Pass |
| CFPP | EN 116 | °C | -18 | Max -10 (Winter) | Pass |
| Cloud Point | EN 23015 | °C | -12 | Report | Report |
| Distillation T10 | ISO 3405 | °C | 195 | Max 195 (Summer) | Pass |
| Distillation T50 | ISO 3405 | °C | 278 | Report | Report |
| Distillation T90 | ISO 3405 | °C | 332 | Max 345 | Pass |
| Distillation T95 | ISO 3405 | °C | 352 | Max 360 | Pass |
| Water Content | EN ISO 12937 | mg/kg | 85 | Max 200 | Pass |
| Lubricity HFRR | ISO 12156-1 | µm | 385 | Max 460 | Pass |
Callout boxes in the live report highlight three columns that cause the most disputes. The Method column cites the exact ISO or EN standard so laboratories cannot substitute an equivalent method without a deviation note. The Limit column reproduces the EN 590 threshold for the declared grade and season; any entry marked "Report" means the standard requires a value but sets no pass or fail limit. The Conformity column uses Pass, Fail or a dash for informational rows; a Fail triggers a non-conformity statement on the final page and usually blocks cargo release under a letter of credit.
The full parameter table with 15 rows from Cetane to Lubricity covers every mandatory test in EN 590 Annex A. Each row lists the parameter name, the normative test method, the unit of measure, the laboratory result, the specification limit and the conformity flag. Buyers should verify that the method column matches the latest edition cited in the standard because SGS occasionally runs an older method version during a transition period and notes it as a deviation.
Callout boxes for Method column, Limit column, and Conformity symbols appear as shaded annotations in the SGS PDF. The Method callout reminds the reader that ISO 5165 is the referee method for Cetane Number while ISO 4264 is a calculated index. The Limit callout shows the seasonal CFPP window; a winter cargo tested at -18 °C meets a -10 °C max but would fail a -20 °C arctic grade. The Conformity callout explains that a dash means the parameter is reported for information only and does not affect the overall pass or fail decision.
The report header contains the legal identifiers that determine whether a bank will accept the certificate under a letter of credit. Every field must be consistent with the commercial invoice, bill of lading and sampling certificate or the document chain breaks.
Job reference, client name, and report date vs test date appear in the top left block. The job reference is a unique alphanumeric code assigned by SGS at sample registration; it is the key for online verification via CertiCheck. The client name must match the applicant on the letter of credit. The report date is when SGS issued the final PDF; the test date range shows when each analysis was performed. A gap of more than five business days between the last test date and the report date often signals a re-test or a deviation investigation.
ISO/IEC 17025, UKAS, DAkkS, COFRAC logo meanings confirm the laboratory's accreditation scope. UKAS indicates the UK national accreditation body, DAkkS the German body and COFRAC the French body. All three logos on one report mean the testing laboratory holds multi-lateral recognition under the EA and ILAC MRA so the certificate is accepted in every EU member state and major trading partners. If only one logo appears, verify that the issuing laboratory's scope covers every test method listed in the table.
Sample ID, grade (B7/B10), sampling point, seal numbers sit in the central header block. The sample ID links the physical jar to the digital record. The grade declaration B7 or B10 sets the FAME limit column in the parameter table. The sampling point describes where the inspector drew the sample such as shore tank 3 manifold or vessel manifold after loading. Seal numbers are the tamper-evident tags applied by the inspector; they must match the numbers on the sampling certificate and the bill of lading remarks column. Any mismatch invalidates the chain of custody and the report cannot support cargo release.
The test parameter table is the core of the EN590 SGS report. Each row represents a single property such as density, sulphur or CFPP. Reading across the row tells you which standard was used, what the lab measured, what the specification allows and whether the sample meets that limit. The conformity column is the final decision gate for cargo release.
| Column Header | Typical Content | What to Verify | Common Pitfall |
|---|---|---|---|
| Method | ISO 3675, EN ISO 12937, SGS Lab Code | Matches EN590 required method list | Obsolete or withdrawn standard cited |
| Unit | kg/m³, mg/kg, °C, µm | Unit matches limit column unit | Unit mismatch hides non-conformity |
| Result | 835.2, 8.5, -12, 380 | Reported to correct significant figures | Rounding masks borderline failure |
| Limit | 820, 845, Max 10, Max -5, Max 460 | Reflects correct grade and season | Wrong seasonal table applied |
| Conformity | Pass, Fail, *, Sub | Consistent with result vs limit and U | Pass shown when result + U exceeds limit |
The table above maps each column to its verification task. The Method column must reference the exact ISO or EN standard mandated by the current EN590 revision. If an SGS internal lab code appears, confirm it maps to the required standard in the report footer. The Unit column must align perfectly with the Limit column; a result in ppm versus a limit in mg/kg will always read as compliant until converted. The Result column should display the measured value with the precision required by the test method. The Limit column must reflect the correct grade (B7 or B10) and the correct seasonal or geographic class for cold flow properties. The Conformity column is not a simple pass or fail; an asterisk often flags measurement uncertainty overlap and a Sub flag indicates the test was subcontracted to another laboratory.
The Method column identifies the exact test procedure used for each parameter. EN590 mandates specific standards such as ISO 3405 for distillation or EN ISO 20846 for sulphur. SGS reports often list the ISO or EN number directly. In some cases an SGS internal laboratory code appears instead. That code must be defined in the report footer or annex with a clear cross-reference to the official standard. If the method column shows an obsolete standard such as ISO 3170 for sampling instead of ISO 3171 the report may not satisfy a letter of credit requirement. Always verify that the method edition year matches the EN590 revision referenced on the cover page.
The Result column shows the measured value. The Limit column shows the specification boundary. Conformity is not decided by a simple comparison of result against limit. ISO/IEC 17025 requires the laboratory to evaluate measurement uncertainty. If the result plus the expanded uncertainty (U) exceeds the upper limit or the result minus U falls below the lower limit the laboratory cannot state unqualified conformity. Many SGS reports handle this by adding an asterisk in the conformity column or a footnote stating the result is within specification but uncertainty overlaps the limit. For cargo release under a letter of credit banks may reject a report where critical parameters such as sulphur or CFPP carry an uncertainty flag. Check the uncertainty budget in the report annex before accepting a borderline pass.
The Conformity column uses a controlled vocabulary. Pass means the result meets the limit with uncertainty considered. Fail means it does not. An asterisk typically means the result is within the limit but the expanded uncertainty interval crosses the limit so the laboratory cannot guarantee conformity at the 95 percent confidence level. A Sub or Subcontracted flag means the test was performed by a laboratory other than the issuing SGS lab. The subcontracted lab must hold its own ISO/IEC 17025 accreditation for that specific method. If the subcontracted flag appears on a critical parameter verify the subcontractor accreditation scope in the report annex. A missing subcontractor accreditation invalidates that test line for most banking and regulatory purposes.
Cetane quality governs ignition delay and combustion noise. The report may show both a measured Cetane Number from the engine test and a calculated Cetane Index from density and distillation data. They are not interchangeable for conformity purposes.
ISO 5165 is the reference engine test. A standardized single cylinder engine runs on the sample fuel and the ignition delay is compared against primary reference fuels. The output is the Cetane Number. ISO 4264 calculates the Cetane Index from the density at 15 °C and the mid-boiling point or the 10, 50 and 90 percent recovery temperatures from the distillation curve. The calculation is fast and inexpensive but it does not capture the effect of cetane improver additives. The engine method does. If the fuel contains 2-ethylhexyl nitrate or other improvers the Cetane Number will be higher than the Cetane Index. The report will list both when the laboratory runs the full suite.
EN590 sets the minimum Cetane Number at 51.0 according to DieselNet (current EN 590). Most European road diesel reports show Cetane Numbers between 52 and 56. Premium grades or winter blends with improvers can reach 58 to 60. The Cetane Index for the same fuels typically falls between 48 and 53. A Cetane Index below 46 often signals a highly paraffinic or heavily cracked blendstock that may struggle to meet the 51.0 engine number without additives according to DieselNet (current EN 590). When reviewing the report note whether the result is reported to one decimal place as required by the test method. A result of 51.0 exactly meets the spec but leaves no margin for measurement uncertainty according to DieselNet (current EN 590).
Both values appear when the laboratory performs the full EN590 test package. The Cetane Number from ISO 5165 is the legal conformity parameter. The Cetane Index from ISO 4264 is supplementary information. If only the Cetane Index is reported the report does not demonstrate conformity with the EN590 Cetane Number requirement. Some sellers provide a Cetane Index only to reduce cost. That report cannot support cargo release under a standard EN590 specification or a letter of credit calling for full EN590 compliance. Always confirm the engine test was performed and the Cetane Number result is explicitly marked Pass in the conformity column.
The EN590 specification sets a density window of 820 to 845 kg/m³ at 15°C and this range governs every mass-to-volume conversion in custody transfer. A result near the lower bound indicates lighter paraffinic diesel while a result near the upper bound signals heavier aromatic content. Both extremes remain compliant but they shift the energy content per litre and the quantity calculated on a bill of lading. The report will list the test method as either ISO 3675 for the hydrometer technique or ISO 12185 for the oscillating U-tube density meter. Modern laboratories overwhelmingly use ISO 12185 because it delivers higher repeatability and is fully automated. The density value on the certificate is always corrected to the 15°C reference temperature using the appropriate petroleum measurement tables regardless of the actual test temperature. According to S&P Global (via Hellenic Shipping News), Europe imported 29.9 million mt of Russian diesel in 2022 and every cargo relied on this corrected density figure to convert weighed tonnes into invoiced cubic metres.
ISO 3675 uses a calibrated glass hydrometer immersed in a temperature-controlled cylinder and the analyst reads the meniscus at eye level. The method requires careful temperature equilibration and a correction calculation using ASTM D1250 tables. ISO 12185 employs an oscillating U-tube density meter where a small sample volume fills a vibrating tube and the period of oscillation correlates directly to density. The instrument applies the temperature correction internally and outputs the result at 15°C automatically. ISO 12185 typically achieves a repeatability of 0.1 kg/m³ compared with 0.5 kg/m³ for the hydrometer method. When the report cites ISO 12185 the buyer can have higher confidence in the precision of the dip-and-pay quantity calculation.
All density results must be reported at the standard reference temperature of 15°C. If the laboratory measures at 20°C or 40°C the raw reading is converted using the petroleum measurement tables defined in ISO 91 or ASTM D1250. The SGS report will show the observed temperature and the correction factor applied. A missing correction factor or a handwritten adjustment is a red flag because it breaks the traceability chain. The final certified value at 15°C is the only figure that should be used for quantity calculations on the commercial invoice and the bill of lading.
Custody transfer in the diesel trade uses dip-and-pay where the shore tank dip volume is multiplied by the certified density at 15°C to determine the mass quantity. A density error of just 1 kg/m³ on a 30,000 m³ cargo shifts the mass by 30 metric tonnes which at current prices represents a significant value discrepancy. The EN590 dip-and-pay procedure relies on the SGS density result being both accurate and defensible. Buyers should verify that the laboratory used ISO 12185, that the temperature correction is documented and that the result falls comfortably within the 820 to 845 kg/m³ window with margin for measurement uncertainty.
The EN590 sulphur limit is 10 mg/kg maximum and this ultra-low threshold defines the Euro 5 and Euro 6 diesel grades. The SGS report will show the result in mg/kg with the test method coded as either ISO 20846 for wavelength-dispersive X-ray fluorescence (XRF) or ISO 20884 for inductively coupled plasma optical emission spectrometry (ICP-OES). Both methods are accredited but they differ in detection limit and matrix sensitivity. Refineries routinely produce diesel well below the limit often in the 3 to 7 mg/kg range. The exact numeric value matters because blenders use the headroom to calculate how much higher-sulphur component they can add while staying compliant.
ISO 20846 uses XRF where the sample is irradiated and the characteristic sulphur X-ray emission is measured. It is fast, non-destructive and suitable for high-throughput screening. The typical limit of quantification is around 3 mg/kg. ISO 20884 uses ICP-OES where the sample is digested and the sulphur emission line is measured in plasma. It offers a lower limit of quantification often below 1 mg/kg and is less susceptible to matrix effects from oxygenates or additives. When the report shows ISO 20884 the result carries higher metrological traceability for dispute resolution. Buyers should note the method code in the method column because a letter of credit may specify one technique over the other.
Some laboratories report sulphur as less than 5 mg/kg when the result falls below their validated limit of quantification. Others report a numeric value such as 3.2 mg/kg with an associated measurement uncertainty. The less-than format creates ambiguity for blenders because the true value could be 1 mg/kg or 4.9 mg/kg. A numeric result allows precise blend calculations and demonstrates the laboratory operates with a lower quantification limit. If the SGS report shows a reporting limit statement the buyer should request the actual numeric result and uncertainty from the laboratory before finalizing blend ratios.
Modern hydrotreaters routinely produce diesel with sulphur content between 3 and 7 mg/kg. This provides a comfortable margin against the 10 mg/kg specification limit and absorbs any measurement uncertainty. A result above 8 mg/kg on an SGS report warrants investigation because it suggests either a hydrotreater upset or contamination during logistics. The conformity column will show Pass for any result at or below 10 mg/kg but prudent buyers track the trend across successive cargoes to detect early signs of quality drift.
The EN 14078 infrared spectroscopy method determines the fatty acid methyl ester (FAME) content in diesel by measuring the carbonyl absorption band near 1745 cm⁻¹. The result is expressed as a volume percentage and appears on the SGS report with the method reference EN 14078 in the test parameter table. A typical B7 grade will show a result between 6.0 and 7.0 %V/V while a B10 grade will read between 9.0 and 10.0 %V/V. The conformity column references the EN 590 limit of 7.0 %V/V max for standard grades or the national annex limit of 10.0 %V/V max where B10 is mandated. Always verify the grade designation in the report header because the same numeric result passes for B10 but fails for B7.
Grade identification is critical because the EN 590 specification allows national annexes to raise the FAME limit from 7.0 %V/V to 10.0 %V/V. The SGS report header normally states the applicable standard such as EN 590:2013+A1:2017 or a national variant like DIN EN 590. If the header cites only the base EN 590 the 7.0 %V/V limit applies. If a national annex is referenced the 10.0 %V/V limit may apply. Buyers must match the grade on the commercial contract to the standard cited on the report. A cargo loaded as B7 in Rotterdam but discharged in a B10 market remains compliant however a B10 cargo delivered into a strict B7 market is off-spec regardless of the test result.
Oxidation stability is measured by the EN 15751 Rancimat method at 110 °C and reported as an induction period in hours. The EN 590 minimum is 20 hours for all FAME-containing grades. A result below 20 hours fails conformity even if the FAME percentage is within limit. The report may also list acid value by EN 14112 as a supplementary indicator; values above 0.10 mg KOH/g suggest oxidative degradation during storage. When the Rancimat result is close to 20 hours request the measurement uncertainty from the laboratory because a result of 20.5 hours with an uncertainty of ±1.5 hours statistically overlaps the fail zone. Blenders should track this parameter across successive cargoes because oxidation stability declines with time and temperature exposure.
Cold flow requirements vary by country and season because EN 590 delegates climate-dependent limits to national annexes. The table below summarizes the most common CFPP and Cloud Point limits applied in Northwest Europe. CFPP is the legal pass or fail criterion while Cloud Point serves as an operational indicator of wax appearance. Always confirm the exact seasonal dates and grade designations in the national annex for the discharge port because transition periods can shift by one to two weeks between years.
| Country | Grade / Season | CFPP Limit (°C) EN 116 | Cloud Point Limit (°C) EN 23015 | Typical Transition Period |
|---|---|---|---|---|
| United Kingdom | Summer | +5 | Report only | 16 Mar, 15 Oct |
| United Kingdom | Winter | -15 | Report only | 16 Oct, 15 Mar |
| Germany | Summer | 0 | Report only | 15 Apr, 30 Sep |
| Germany | Winter | -20 | Report only | 1 Nov, 28 Feb |
| Germany | Arctic / Severe Winter | -32 to -44 | Report only | Regional / Altitude based |
| France | Summer | 0 | Report only | 1 Apr, 31 Oct |
| France | Winter | -15 | Report only | 1 Nov, 31 Mar |
| Netherlands | Summer | 0 | Report only | 1 Apr, 30 Sep |
| Netherlands | Winter | -20 | Report only | 1 Oct, 31 Mar |
| Scandinavia (NO SE FI DK) | Summer | -5 to 0 | Report only | 1 May, 30 Sep |
| Scandinavia (NO SE FI DK) | Winter | -26 to -32 | Report only | 1 Oct, 30 Apr |
| Scandinavia (NO SE FI DK) | Arctic | -44 | Report only | Northern regions year-round |
The table shows that CFPP limits range from +5 °C in UK summer to -44 °C in Scandinavian arctic grades. Cloud Point is reported for information only in all listed countries because EN 590 does not set a mandatory Cloud Point limit. Germany applies a distinct arctic grade for alpine regions while Scandinavia uses a three-tier system covering summer winter and arctic zones. The transition periods are indicative; the legally binding dates are published annually by each national standards body. When reviewing an SGS report check the sampling date against the applicable seasonal window for the discharge port. A cargo sampled on 1 October in Rotterdam falls under the Dutch winter grade requiring -20 °C CFPP while the same cargo sampled on 30 September meets the summer grade of 0 °C CFPP.
Trade Diesel & EN590 on Global Trade Plaza: diesel on Global Trade Plaza, diesel suppliers and exporters, diesel buyers and importers, en 590 10 ppm diesel, diesel fuel en590 buy requirement, automotive gas oil, petroleum oil related products on Global Trade Plaza, diesel fuel en590 euro 5 10ppm netherlands, diesel fuel en590 usdl 10 ppm, en590 diesel 10ppm ulsd, marine fuel gas oil mgo, diesel fuel en 590 ulsd 10 ppm ulsd 50ppm.
Related reading: EN590 10 PPM Diesel: Specifications and Global Uses.
Verify the report header identifiers against the commercial invoice, bill of lading and sampling certificate before accepting the certificate under a letter of credit. Confirm every Method column entry matches the current EN 590 revision and that any SGS internal lab code cross-references to the official standard in the footer. Check that Limit values reflect the declared grade and seasonal class, especially for CFPP and Cloud Point, and treat any Fail or unresolved asterisk on critical parameters as a block to cargo release.
Use the annotated sample as a checklist when the next certificate arrives so you can confirm each row before the shipment moves. For live buyer or supplier verification on the next trade cycle, start at Global Trade Plaza.
Standard EN590 SGS reports are typically issued within three to five business days after the laboratory receives the sample. Complex matrices or subcontracted parameters such as detailed hydrocarbon analysis can extend the timeline by several days. Always confirm the expected delivery date at sample registration to align with letter of credit presentation deadlines.
An SGS test report is a formal certificate issued by an ISO/IEC 17025 accredited laboratory detailing the analytical results of a product sample against a specific standard. For EN590 diesel it lists 15 mandatory parameters from Cetane Number to Lubricity with method codes, limits and conformity flags. Banks and customs authorities rely on this document to verify cargo compliance before release.
A typical EN590 SGS report example displays a header with job reference, client name, sampling point and accreditation logos followed by a 15-row parameter table. The table columns show Parameter, Test Method, Unit, Result, Limit and Conformity for properties such as Density at 15°C, Sulphur Content and CFPP. Redacted samples replace commercial identifiers with placeholders for training use.
EN590 caps sulphur at 10.0 mg/kg maximum using ISO 20846 (XRF) or ISO 20884 (ICP-OES) as the referee methods according to DieselNet (current EN 590 / Fuel Quality Directive). The method code on the report must match the technique required by the letter of credit because XRF and ICP-OES have different precision profiles. Always verify the method column cites the correct ISO standard edition.
FAME content for B7 grade must not exceed 7.0 % V/V while B10 grade allows up to 10.0 % V/V per EN 14078. The grade declared in the report header sets the applicable limit column in the parameter table. Oxidation stability minimum of 20.0 hours per EN 15751 applies to both grades and appears on the adjacent row.
CFPP (Cold Filter Plugging Point) is the mandatory pass/fail parameter with seasonal maximum limits such as -10 °C for winter or -5 °C for summer per EN 116. Cloud Point per EN 23015 is a report-only parameter with no pass/fail threshold in the standard. The Limit column must reflect the declared seasonal class for the cargo destination.
Pass means the result meets the specification limit accounting for measurement uncertainty. Fail means the result exceeds the limit and typically blocks cargo release under a letter of credit. A dash indicates an informational parameter with no conformity decision. An asterisk flags measurement uncertainty overlap where the result plus uncertainty crosses the limit.
SGS CertiCheck is an online portal where users enter the job reference number from the report header to confirm the certificate matches the laboratory's issued record. The portal displays the report status, issue date and parameter summary. Any discrepancy between the PDF and the portal invalidates the document for letter of credit presentation.
EN590 sets a maximum limit of 360 °C for the T95 distillation point per ISO 3405. This parameter controls the heavy end of the boiling range to prevent injector deposits and excessive smoke. The report must show the T95 result with a Pass flag against the 360 °C maximum for the cargo to meet specification.
Lubricity is measured by HFRR (High Frequency Reciprocating Rig) per ISO 12156-1 with a maximum wear scar diameter of 460 µm. This limit protects fuel injection equipment from excessive wear in ultra-low sulphur diesel. A result above 460 µm yields a Fail flag and usually prevents cargo release until re-blending or additive treatment is verified.
Oxidation stability must be a minimum of 20.0 hours measured by the Rancimat method per EN 15751. This test ensures the fuel resists gum and sediment formation during storage, especially critical for B7 and B10 blends containing FAME. The report shows the hours result with a Pass flag only if the value meets or exceeds the 20 hour threshold.
Measurement uncertainty (U) expands the result into an interval; conformity is assessed by comparing this interval against the specification limit. If the interval crosses the limit an asterisk appears in the Conformity column instead of Pass or Fail. The laboratory's reported uncertainty budget for each method determines whether a borderline result is accepted or rejected.
An asterisk in the Conformity column primarily flags measurement uncertainty overlap where the result plus uncertainty crosses the specification limit. A separate Sub flag in the same column indicates the test was subcontracted to another accredited laboratory. Both symbols require review: the asterisk for technical acceptance risk and the Sub for traceability to the subcontractor's accreditation scope.